{"id":313,"date":"2024-01-13T08:18:22","date_gmt":"2024-01-13T16:18:22","guid":{"rendered":"http:\/\/deltaclab.com\/?page_id=313"},"modified":"2024-01-13T08:46:01","modified_gmt":"2024-01-13T16:46:01","slug":"experiment-2","status":"publish","type":"page","link":"https:\/\/deltaclab.com\/?page_id=313","title":{"rendered":"Experiment 2"},"content":{"rendered":"\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"615\" src=\"http:\/\/deltaclab.com\/wp-content\/uploads\/2024\/01\/Experiment_2a-1024x615.jpg\" alt=\"\" class=\"wp-image-277\" srcset=\"https:\/\/deltaclab.com\/wp-content\/uploads\/2024\/01\/Experiment_2a-1024x615.jpg 1024w, https:\/\/deltaclab.com\/wp-content\/uploads\/2024\/01\/Experiment_2a-300x180.jpg 300w, https:\/\/deltaclab.com\/wp-content\/uploads\/2024\/01\/Experiment_2a-768x461.jpg 768w, https:\/\/deltaclab.com\/wp-content\/uploads\/2024\/01\/Experiment_2a-1536x922.jpg 1536w, https:\/\/deltaclab.com\/wp-content\/uploads\/2024\/01\/Experiment_2a.jpg 1651w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<ul class=\"has-black-color has-white-background-color has-text-color has-background has-link-color has-medium-font-size wp-block-list wp-elements-cdb4e6a9a728b41403e75daa2f7401d3\">\n<li><strong>Experiment: 2a<\/strong>&nbsp;(In anechoic chamber) \u2013 Peak Values<\/li>\n\n\n\n<li>September14, 2023:<\/li>\n\n\n\n<li>Frequency in MHz: 6<\/li>\n\n\n\n<li>Sampling Rate of oscilloscope: 25 MHz<\/li>\n\n\n\n<li>Bit Selection of oscilloscope: 16<\/li>\n\n\n\n<li>Effective bit resolution: 11<\/li>\n\n\n\n<li>Anisotropic difference: 788 mV<\/li>\n\n\n\n<li>Input Voltage: 20 volts<\/li>\n\n\n\n<li>(Oscilloscope probe was not used during this experiment)<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"615\" src=\"http:\/\/deltaclab.com\/wp-content\/uploads\/2024\/01\/Experiment_2b-1024x615.jpg\" alt=\"\" class=\"wp-image-278\" srcset=\"https:\/\/deltaclab.com\/wp-content\/uploads\/2024\/01\/Experiment_2b-1024x615.jpg 1024w, https:\/\/deltaclab.com\/wp-content\/uploads\/2024\/01\/Experiment_2b-300x180.jpg 300w, https:\/\/deltaclab.com\/wp-content\/uploads\/2024\/01\/Experiment_2b-768x461.jpg 768w, https:\/\/deltaclab.com\/wp-content\/uploads\/2024\/01\/Experiment_2b-1536x922.jpg 1536w, https:\/\/deltaclab.com\/wp-content\/uploads\/2024\/01\/Experiment_2b.jpg 1651w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<ul class=\"has-black-color has-white-background-color has-text-color has-background has-link-color has-medium-font-size wp-block-list wp-elements-faae3e8852c6814057d5709f4054d156\">\n<li><strong>Experiment: 2b<\/strong>&nbsp;(In anechoic chamber) &#8211; Vrms<\/li>\n\n\n\n<li>September 14, 2023:<\/li>\n\n\n\n<li>Frequency in MHz: 6<\/li>\n\n\n\n<li>Sampling Rate of oscilloscope: 25 MHz<\/li>\n\n\n\n<li>Bit Selection of oscilloscope: 16<\/li>\n\n\n\n<li>Effective bit resolution: 11<\/li>\n\n\n\n<li>Anisotropic difference: 569 mV<\/li>\n\n\n\n<li>Input Volts: 20<\/li>\n\n\n\n<li>(Oscilloscope probe was not used during this experiment)<\/li>\n<\/ul>\n\n\n\n<p class=\"has-black-color has-white-background-color has-text-color has-background has-link-color has-medium-font-size wp-elements-c36ab56d1572c980559075545252fb15 wp-block-paragraph\">Experiment 2 was completed at the University of Nevada in Reno in the university\u2019s anechoic chamber.&nbsp; This is a specialized chamber that is isolated from all radio frequency interference (RFI).&nbsp; It also has special foam tiles that prevent RF reflection in the chamber from equipment that is being tested.&nbsp; The purpose of completing this experiment in this special chamber was to rule out RFI as a cause of the anisotropic difference that is noted in results of this experiment.&nbsp; Additionally, during this experiment I obtained peak values and Vrms values from the instrument.&nbsp; It should be noted that during this experiment an oscilloscope probe was not utilized for obtaining the measurement.&nbsp; For this measurement, electrical wire was run from the assigned measurement location to a BNC adapter connected to a coaxial cable that was then run to the oscilloscope input. &nbsp;An obvious anisotropic difference was obtained and RFI was ruled out as a cause of the anisotropic difference.&nbsp;<\/p>\n\n\n\n<p class=\"has-black-color has-white-background-color has-text-color has-background has-link-color has-medium-font-size wp-elements-e29bc0aff0b93b5c400e19b81168f17a wp-block-paragraph\">To understand more about oscilloscope probes and this experiment, see the FAQ on this website.<\/p>\n\n\n\n<h2 class=\"wp-block-heading has-text-align-center\"><strong><a href=\"https:\/\/docs.google.com\/spreadsheets\/d\/e\/2PACX-1vTbC-xOJDtVhUs_8RuYMlQ8pk0h_qekihbWceODLgzRRZ79FaDHf5lyq1SToL6ZmJV0zYvHDMrWayv2\/pubhtml?gid=1113762983&amp;single=true\">Click Here for Raw Data<\/a><\/strong><\/h2>\n","protected":false},"excerpt":{"rendered":"<p>Experiment 2 was completed at the University of Nevada in Reno in the university\u2019s anechoic chamber.&nbsp; This is a specialized<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":52,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-313","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/deltaclab.com\/index.php?rest_route=\/wp\/v2\/pages\/313","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/deltaclab.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/deltaclab.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/deltaclab.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/deltaclab.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=313"}],"version-history":[{"count":7,"href":"https:\/\/deltaclab.com\/index.php?rest_route=\/wp\/v2\/pages\/313\/revisions"}],"predecessor-version":[{"id":353,"href":"https:\/\/deltaclab.com\/index.php?rest_route=\/wp\/v2\/pages\/313\/revisions\/353"}],"up":[{"embeddable":true,"href":"https:\/\/deltaclab.com\/index.php?rest_route=\/wp\/v2\/pages\/52"}],"wp:attachment":[{"href":"https:\/\/deltaclab.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=313"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}